Siemens S7-1200 G2: Memory, I/O Changes and Migration Considerations

  • Josh Zimmerle
  • 650 reads

The S7-1200 G2 adds memory and a smaller footprint, but migration requires checking I/O mapping, feature gaps and motion objects.

Siemens S7-1200 G2: Memory, I/O Changes and Migration Considerations

The Siemens SIMATIC S7-1200 G2 brings more memory and processing performance to the compact-controller family, in a smaller footprint. For engineers weighing an upgrade, the main design question is whether the new CPU’s built-in I/O and supported features fit the existing machine. The G2 can work with existing remote I/O and drives, but it cannot use the original S7-1200’s I/O cards, and its built-in analog channels differ from those on first-generation models.

Model range and onboard I/O

The current G2 range described here has two models: the S7-1212 G2 and S7-1214 G2. Both are available with AC or DC power inputs, DC or relay outputs, and a failsafe option for safety applications. Their digital I/O counts match the corresponding first-generation 1212 and 1214 CPUs, while the G2 models omit built-in analog input channels. An SB 1233 analog input signal board, part number 6ES7233-4HD50-0XB0, can add analog inputs.

The memory figures are split into program memory, working memory and retentive memory for the G2. The first-generation table gives program and working memory together, so the figures should be read in the categories shown rather than treated as directly equivalent totals.

CPUBuilt-in I/OProgram memoryWorking memoryRetentive memory
S7-1212 G28DI/6DO150kB500kB20kB
S7-1214 G214DI/10DO100kB750kB20kB

For comparison, the first-generation S7-1212 has 8DI/6DO/2AI, 100kB of program and working memory, and 10kB of retentive memory. The S7-1214 has 14DI/10DO/2AI, 150kB of program and working memory, and 10kB of retentive memory. The broader first-generation lineup also includes the 1211, 1215 and 1217. The 1215 and 1217 each list 14DI/10DO/2AI/2AO, with 200kB and 250kB of program and working memory respectively; both have 10kB of retentive memory.

That range matters when selecting a replacement: the G2 models listed here correspond most directly to the 1212 and 1214, rather than covering every first-generation CPU configuration. Where analog signals are involved, the replacement plan needs to account for added I/O hardware and revised addresses.

Compatibility and feature limits

The G2 retains the compact controller role, with built-in I/O suited to small machines and the option to expand through additional I/O and remote I/O. Existing remote I/O and drives remain usable, but the original S7-1200 I/O cards are not reverse-compatible with the G2. That makes a cabinet and network inventory a useful early step: identify which signals use onboard channels, local cards, remote racks and drives before settling on the CPU model.

With firmware V4.1, the G2 still lacks support for non-optimized blocks, enabling outputs in stop, and AS-I Control. Teleservice has also been replaced by newer web services and other methods. These gaps may matter more than the memory increase in machines that depend on a particular block type, output behavior or AS-I setup. If an application relies on one of these functions, the engineering team will need to assess available workarounds or consider the S7-1500 series.

The G2 may serve as a replacement in many applications, but the hardware fit alone doesn’t establish functional equivalence. The absence of analog inputs, I/O-card incompatibility and the listed feature gaps all call for a project review before a change is scheduled.

Hardware selection flowchart for upgrading legacy Siemens SIMATIC S7-1200 (G1) controllers to the newer SIMATIC S7-1200 G2 generation.

Project conversion and address checks

Conversion requires TIA Portal version 20 or higher. The migration begins by adding an S7-1200 G2 CPU to the existing project, then transferring the PLC data types, external source files, PLC tags, program blocks and technology objects. Watch and force tables and traces can also be copied, or recreated for the new CPU.

Devices & networks editor in Network view inside Siemens TIA Portal.

During tag migration, check that each address still maps to the intended physical input or output. Analog channels deserve particular attention: built-in analog inputs start at %IW64, while external analog cards tend to start at %IW96. Since the G2 models described here have no built-in analog inputs, signals that previously used onboard channels may need to move to an I/O card. A copied tag can look valid in the project while pointing at a different physical channel, so verify the hardware configuration alongside the software addresses.

Hardware and I/O configuration in Siemens TIA Portal for a SIMATIC S7-1214C DC/DC/DC PLC.
TIA Portal configuration screen featuring a Siemens SIMATIC S7-1200 G2 CPU 1214C DC/DC/DC PLC.

Motion control and technology objects also need hands-on conversion. Their implementation has changed slightly, while the G2’s motion capabilities have expanded. Teams should review and adapt these objects in the target project rather than assume a direct copy will preserve behavior. Once the hardware and software changes are in place, compile the PLC project and resolve reported errors or missing blocks.

What the upgrade decision hinges on

The S7-1200 G2’s increased memory and smaller footprint make it a candidate for compact machines where the 1212 or 1214 class fits the I/O requirement. The practical effort lies in confirming that the chosen model covers the signals, that local I/O hardware can be replaced or reassigned, and that the application doesn’t depend on unsupported features.

For an existing installation, the migration is best treated as a hardware and software review together. Confirm the CPU and I/O inventory, map analog addresses, adapt motion objects, and check the completed project by compiling it. Those checks show whether the G2’s capacity and physical fit translate into a workable replacement for the specific machine.