Synchronous 8-Bit Counter Divides Frequencies by Even Ratios up to 242
- Brian Dipert
- 469 reads
An SN74ALS86x counter and one logic chip produce even-number frequency divisions with a 50:50 output, avoiding an uncertain asynchronous reset pulse.

A synchronous counter can make an even-ratio frequency divider more predictable without adding a third chip. The circuit uses an SN74ALS86x 8-bit bidirectional synchronous counter and one logic chip to produce a 50:50 square wave at selected division ratios, including ratios up to 242. Its key design change addresses a timing uncertainty in an earlier two-chip asynchronous circuit: the counter’s reset pulse depended on a datasheet-unspecified timing relationship.


Why use a synchronous count cycle?
In the earlier circuit, an asynchronous reset signal had to remain active long enough to clear the counter. The datasheet did not guarantee that the pulse produced by the logic would meet that requirement in every case. The timing was plausible, but a design that relies on an unspecified pulse width leaves room for doubt about reliable operation.
The synchronous alternative makes the counter’s state change on a positive-going clock edge. That gives the reset and output-toggle actions a defined place in the count sequence. The design still uses two chips, so the improvement in timing confidence does not come with a more elaborate chip count.
The counter is an SN74ALS86x 8-bit up/down device with a single synchronous clock input. As described in the 867/869 datasheet, its four mode control inputs—S0, S1, -ENT and -ENP—select whether a rising clock edge increments, decrements or parallel-loads the count. In this circuit, the counter advances until a terminal state is recognized by gate U2a.

One terminal detection sets up two actions
When U2a detects the selected terminal state, its output at pin 6 goes low. That signal enables the counter’s parallel-load operation. On the next positive-going clock edge, the counter loads the values presented at its parallel inputs. This single synchronous event both begins the next count cycle and changes the output state.
- Bits A through G load a new starting state. The connections from the counter’s seven lower-order outputs to U2a’s inputs determine which count state triggers the load, and therefore the division ratio. Tying selected inputs to +5 V instead of ground provides additional choices.
- Bit H loads the complement of its previous state, through the inversion provided by U2b. It therefore toggles once per counting cycle. A full output period spans two cycles, producing a 50:50 square wave.
That second action is useful because many frequency dividers produce an output whose high and low intervals depend on the details of the count sequence. Here, toggling the output once at the end of each cycle makes the duty cycle equal across the two halves of the output period.
Configuring the division ratio
U2a decodes four inputs from a seven-bit counter state. That limited decode means the circuit cannot select every one of the 128 possible states. It still supports many practical even division ratios, with the examples below showing how the connections set the count length. The ratio is twice the number of input-clock cycles in one counting cycle because the output toggles at each cycle boundary and needs two toggles to complete a full period.
| Division ratio | Implementation connections |
|---|---|
| Divide by 2 = 2 × (0 + 1) | +5 to J, K, L and M |
| Divide by 10 = 2 × (4 + 1) | Qc to J; +5 to K, L and M |
| Divide by 48 = 2 × (16 + 4 + 2 + 1 + 1) | Qa to J; Qb to K; Qc to L; Qe to M |
| Divide by 100 = 2 × (32 + 16 + 1 + 1) | Qa to J; Qe to K; Qf to L; +5 to M |
| Divide by 200 = 2 × (64 + 32 + 2 + 1 + 1) | Qa to J; Qb to K; Qf to L; Qg to M |
The examples include common ratios such as 10, 48, 100 and 200, while the circuit’s stated range extends to even ratios of 242. These are configuration choices made through the counter-to-decode connections; they are not separate divider stages. The table also shows that a +5 V connection can stand in for a counter output when setting the decode pattern.
What the design changes in practice
The appeal is the balance between predictable timing and a compact parts count. The earlier asynchronous approach raised a legitimate question about whether its reset pulse would always clear the counter. In this version, the terminal detection prepares a parallel load, and the counter acts on that request at its clock edge. The result is a synchronous count sequence while retaining the two-chip implementation.
The trade-off is that the available ratios depend on the decoder’s four-input view of the counter state, so the circuit does not offer arbitrary programming of every possible count. For a selected even ratio, though, the wiring examples provide a direct way to configure the terminal state and preserve a 50:50 output. The practical takeaway is a small divider design whose timing behavior follows the synchronous counter’s specified clocked operation, with the desired ratio set by a handful of logic connections.